Datamax-oneil Class Series II Programmer’s Manual Instrukcja Użytkownika Strona 146

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 334
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 145
Label Formatting Command Functions
132 Class Series 2 Programmer’s Manual
M Select Mirror Mode
This command instructs the printer to “mirror” all subsequent print field records,
producing fields that are transposed visually.
Syntax:
M
Sample:
<STX>L
161100003200010 NOT MIRRORED<CR>
M<CR>
161100003000400 MIRRORED<CR>
E
Printed Result:
m Set Metric Mode
This command sets the printer to measure in metric. When this command is sent, all
measurements will be interpreted as metric values, (e.g., a column offset of 0010 will be
interpreted as 1.0 mm).
Syntax:
m
Sample:
<STX>L<CR>
m
141100001000100SAMPLE LABEL<CR>
E
The sample above prints the text (SAMPLE LABEL) starting at
location coordinates 10.0 mm, 10.0 mm.
n Set Inch (Imperial) Mode
This command sets the printer to measure in inches. When this command is sent, all
measurements will change to inches. Default mode, and is menu selectable.
Syntax:
n
Sample:
<STX>L<CR>
n
141100001000100SAMPLE LABEL<CR>
E
The sample above prints the text (SAMPLE LABEL) starting at
location coordinates 1.0 inch, 1.0 inch.
Przeglądanie stron 145
1 2 ... 141 142 143 144 145 146 147 148 149 150 151 ... 333 334

Komentarze do niniejszej Instrukcji

Brak uwag