Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 73
(MCC) Module Command – This command adjusts the size of Flash module on the
optional Expansion Card according to the table below (see Appendix K for
appropriate module details):
Value Module Command Units / Interpretation
Zxx
Where xx =
Size: 1 – 7 Mbytes. This is the amount to be allocated to
Module Z; any remaining memory will be allocated to Module F.
Gxx
Where xx =
Size: 1 – 56, in 128 Kbytes blocks. This is the amount to be
allocated to Module G; any remaining memory will be allocated
to Module X.
Table 5-4: Module Command
(ML) Maximum (Label) LengthSee <STX>M for command details.
(MM) Menu Mode – This command sets the menu access level of the printer –
where User is a basic listing of menu settings and controls, and Advanced is a full
menu listing.
(MT) Media Type This command selects the printing method: Direct Thermal for
use with heat sensitive media or Thermal Transfer for use with media requiring a
ribbon to create an image. (For Non-Display models also see the <STX>KD
command.)
(MV) Mark ValueThis command sets threshold value for the reflective media
sensor’s “mark” parameter.